Component Family |
Databases/Teradata |
|
Function |
As the combination of tTeradataFastLoad, tTeradataMultiLoad, tTeradataTPump, and tTeradataFastExport, tTeradataTPTUtility writes the incoming data to a |
|
Purpose |
tTeradataTPTUtility writes the |
|
Basic settings Data file |
Property Type |
Either Built-In or Repository. Since version 5.6, both the Built-In mode and the Repository mode are |
|
|
Built-In: No property data stored |
|
|
Repository: Select the repository |
|
Filename |
Specify the file to save the incoming data. |
|
Append |
Select this check box to append the incoming data in the file |
Connection |
Property Type |
Either Built-In or Repository. Since version 5.6, both the Built-In mode and the Repository mode are |
Built-In: No property data stored |
||
Repository: Select the repository |
||
Execution platform |
Select the Operating System that will be used to run the Job, either Windows or Unix. |
|
TDPID |
Specify the Teradata director program identifier. It can be either |
|
Database name |
Specify the name of the Teradata database. |
|
Username and |
Specify the username and the password for the Teradata database To enter the password, click the […] button next to the |
|
|
Schema and Edit |
A schema is a row description. It defines the number of fields to be processed and passed on Since version 5.6, both the Built-In mode and the Repository mode are NoteAvoid using a Teradata database keyword as a Db |
|
|
Built-In: You create and store the schema locally for this |
|
|
Repository: You have already created the schema and |
Click Edit schema to make changes to the schema. If the
|
||
Consumer Operator |
Select a consumer operator from the drop-down list.
For more information about Teradata consumer operators, see http://www.info.teradata.com/HTMLPubs/DB_TTU_14_00/index.html#page/Load_and_Unload_Utilities/B035_2445_071A/2445ch02.109.18.html. |
|
Action On Data |
Select an action to be performed on the data from the drop-down list.
NoteYou must specify at least one column as the primary key on This list field appears only when the Update or Stream |
|
Producer Operator |
Select a producer operator from the drop-down list. Currently, DataConnector: accesses files For more information about Teradata producer operators, see http://www.info.teradata.com/HTMLPubs/DB_TTU_13_10/index.html#page/Load_and_Unload_Utilities/B035_2445_020A/2445ch02.04.16.html. |
|
|
Table |
Specify the name of the table to be written into the Teradata |
|
Script generated folder |
Specify the directory under which the Teradata Parallel |
|
Error file |
Specify the file in which log messages will be recorded. |
Advanced settings |
Row separator |
Character, string or regular expression to separate rows. |
|
Field separator |
Character, string or regular expression to separate fields. |
|
Include header |
Select this check box to include the column header to the |
|
Encoding |
Select the encoding from the list or select Custom and define it manually. This field is |
Set Script Parameters |
Select this check box to define script parameters, which will be |
|
|
Load Operator |
Specify the load operator. This field appears only when the Set Script |
|
Data Connector |
Specify the data connector. This field appears only when the Set Script |
|
Job Name |
Specify the name of a Teradata Parallel Transporter Job which is For further information about the tbuild This field appears only when the Set Script |
|
Layout Name (schema) |
Specify a schema for the data to be loaded. This field appears only when the Set Script |
|
Define Log table |
Select this check box to specify a log table so that log messages |
|
Return mload error |
Select this check box to specify the exit code number to indicate |
|
Define character set |
Select this check box to specify the character encoding to be used |
|
Apply TPT consumer operator optional attributes |
Select this check box to define optional attribute(s) for the For more information about optional attributes of each consumer |
|
Optional attributes |
Click the [+] button below the
For more information about the attribute value definition, see This table appears only when the Apply TPT |
|
tStatCatcher Statistics |
Select this check box to collect the log data at the component |
Global Variables |
EXIT_VALUE: the process exit code. This is an After ERROR_MESSAGE: the error message generated by the A Flow variable functions during the execution of a component while an After variable To fill up a field or expression with a variable, press Ctrl + For further information about variables, see Talend Studio |
|
Usage |
Preceded by an input component, tTeradataTPTUtility writes the incoming data to a |
|
Limitation |
The Teradata client tool with the Teradata Parallel Transporter |
For a related scenario, see Scenario: Loading data into a Teradata database.